Fastwall MINIMA glazed system with 10mm toughened glass and clear dryjoint
system tested to BS 5234: 1992 : Medium grade
The following are the relevant parts of the test, along with details
of the standard required and the results achieved:
Part A: Determination of partition stiffness |
|
Standard
|
Test result
|
Maximum deflection |
20mm
|
9.72mm
|
Maximum residual deflection |
3mm
|
0.58mm
|
Part B: Determination of surface damage by small
hard body impact |
|
Test result
|
Test laboratory applies judgement regarding nature
and extent of surface damage |
Zero damage
|
Part C: Determination of resistance to damage by
impact from a large soft body |
|
Standard
|
Test result
|
Maximum permanent deformation Mid glass |
2mm
|
0.1mm
|
Maximum permanent deformation Joint between panels |
2mm
|
0.0mm
|
Part D: Determination of resistance to perforation
by small hard body impact |
|
Test result
|
No perforation permitted |
Conformed
|
Part E: Determination of resistance to structural
damage by multiple impacts from a large soft body |
|
Test result
|
No collapse or dislocation of the partition or its
fixings shall occur |
Conformed
|
Part F: Determination of the effects of door slamming
(1) |
|
Test result
|
No damage to the partition shall occur not shall the
door frame fittings or architrave become detached or loose |
Conformed
|
Part F: Determination of the effects of door slamming
(2) |
Closing joint shall not be permanently displaced by
more than: |
Standard
|
Test result
|
Pre-slam test |
3mm
|
0.04mm
|
Main test |
1mm
|
0.51mm
|